UPS 500W pure sine wave inverter with charger | ||||
Model | sp12/220-500LC | sp24/220-500LC | sp48/220-500LC | |
Continuous Power | 500W | |||
Surge Power | 1000W | |||
Frequency | 50HZ or 60HZ | |||
Wave Form | Pure Sine Wave | |||
AC Regulation | THD<3%(Linear Load) | |||
Output Efficiency | 92% | |||
DC Voltage | DC12V | DC24V | DC48V | |
AC Voltage | 220VAC ±5% | |||
No Load Current Draw | 0.55A | 0.3A | 0.15A | |
DC Voltage Range | 10-15V | 20-30V | 40-60V | |
Low Voltage Shut Down | 10V | 20V | 40V | |
Over Voltage Shut Down | 15V | 30V | 60V | |
Low Voltage Recovery | 12.5V | 25V | 50V | |
Charging Voltage | 14.6V | 29.2V | 58.4V | |
Floating Charge Voltage | 13.6V | 27.2V | 54.4V | |
Charging Current | ≤10A | ≤5A | ≤2.5A | |
Transfer Time | ≤9MS | ≤9MS | ≤9MS | |
Grid Input Draw | 220VAC ±10% | |||
Protection | Low Voltage/Over Voltage | LED Alarm and Automatic Recovery. | ||
Overload | LED Alarm and Automatic Recovery. | |||
Over Temperature | LED Alarm and Automatic Recovery. | |||
Short Circuit | LED Alarm and Automatic Recovery. | |||
Working Temperature | -10°- +50° | |||
Storage Temperature | -30°- +70° | |||
Production Size | 365*165*85(mm) | |||
Package Size | 420*240*150(mm) | |||
N.W/G.W | 3.4/4.2(kg) | |||
Warranty | 1 Years | |||
Cooling Way | Intelligent Cooling Fan |
UPS 500W pure sine wave inverter with charger | ||||
Model | sp12/220-500LC | sp24/220-500LC | sp48/220-500LC | |
Continuous Power | 500W | |||
Surge Power | 1000W | |||
Frequency | 50HZ or 60HZ | |||
Wave Form | Pure Sine Wave | |||
AC Regulation | THD<3%(Linear Load) | |||
Output Efficiency | 92% | |||
DC Voltage | DC12V | DC24V | DC48V | |
AC Voltage | 220VAC ±5% | |||
No Load Current Draw | 0.55A | 0.3A | 0.15A | |
DC Voltage Range | 10-15V | 20-30V | 40-60V | |
Low Voltage Shut Down | 10V | 20V | 40V | |
Over Voltage Shut Down | 15V | 30V | 60V | |
Low Voltage Recovery | 12.5V | 25V | 50V | |
Charging Voltage | 14.6V | 29.2V | 58.4V | |
Floating Charge Voltage | 13.6V | 27.2V | 54.4V | |
Charging Current | ≤10A | ≤5A | ≤2.5A | |
Transfer Time | ≤9MS | ≤9MS | ≤9MS | |
Grid Input Draw | 220VAC ±10% | |||
Protection | Low Voltage/Over Voltage | LED Alarm and Automatic Recovery. | ||
Overload | LED Alarm and Automatic Recovery. | |||
Over Temperature | LED Alarm and Automatic Recovery. | |||
Short Circuit | LED Alarm and Automatic Recovery. | |||
Working Temperature | -10°- +50° | |||
Storage Temperature | -30°- +70° | |||
Production Size | 365*165*85(mm) | |||
Package Size | 420*240*150(mm) | |||
N.W/G.W | 3.4/4.2(kg) | |||
Warranty | 1 Years | |||
Cooling Way | Intelligent Cooling Fan |